  • Expensive history of unexpected and catastrophic extruder gearbox failures
  • MHC-Memo gives early detection of deterioration in an internal oil-pump
  • Catastrophic failure prevented allowing identification of the root cause
 
Home > Industries > Food and Beverage

Keeping Walkers running

Food
We are impressed with the results the Memo is giving us - and how easy it is to use”  Dave Pickup, Walkers Snack

An MHC Memo instrument was evaluated at a pilot site resulting in significant savings. Following on from this, the same approach has been rolled out throughout all UK sites. The present case study is just one example of the benefits this has given the Walkers Group. Over a period of years, two major gearboxes had failed catastrophically at one particular Walkers site. In each case, the internal damage was so complete that there were no clues as to the root cause of the failures. In addition to the extensive damage, the unexpected failure resulted in lost production time and serious consequential costs.
Food graph

Periodic measurements were initiated using the MHC-Memo instrument when a replacement extruder gearbox was installed in January 2003. The trend of Distress® values for the first 9 months of operation of this gearbox is shown in the accompanying plot. From this, it can be clearly seen that the Distress® reading increased significantly in June 2003 and first tripped the alarm level (set at Distress® = 15) in July 2003.
 
Although oil analysis showed nothing untoward, the gearbox was replaced (with minimum disruption to production) and it could be immediately seen that the replacement gearbox exhibited normal levels of Distress®. When the suspect gearbox was stripped down it revealed that the internal oil pump had failed with significant damage to a bearing race.
Walkers inlet pump 2
The breakdown of the oil pump would have rapidly led to extensive internal damage and the complete failure of this gearbox. This suggests that the brief dip in the Distress® readings on 2nd September corresponded to the final failure of the oil pump and the subsequent rapid rise corresponded to oil starvation in critical parts (a pre-cursor to what would have been total catastrophic failure). The main findings can be summarised as follows: 
 
  • Previously 2 gearboxes had failed catastrophically at great cost
  • The MHC-Memo has been shown to provide a simple and effective warning of impending failure, allowing gearbox replacement to be planned so as to minimise disruption to production and secondary damage
  • On-going cost savings are anticipated as future gearbox degradation is detected and acted upon
 